title: "Implementer: Interface Register (IDK-13)"
date: 2026-11-08
description: "How the IDK-13 interface register runs as a register in Implementer, with a nine-state lifecycle, legacy decisions and gate evidence."
author: "Dariusz Mysliwiec"
intro_image: "https://www.ifs-erp.com/images/articles/implementer-idk-13-interface-register-en-185f2e13.webp"
fulltext_image: "https://www.ifs-erp.com/images/articles/implementer-idk-13-interface-register-en-185f2e13.webp"
categories:
  - name: "Implementation docs kit"
    url: "https://www.ifs-erp.com/implementation-docs-kit.md"
tags:
  - name: "IFS Cloud"
    url: "https://www.ifs-erp.com/tags/ifs-cloud.md"
  - name: "Implementer"
    url: "https://www.ifs-erp.com/tags/implementer-en.md"
---

# Implementer: Interface Register (IDK-13)

![Implementer: Interface Register (IDK-13)](https://www.ifs-erp.com/images/articles/implementer-idk-13-interface-register-en-185f2e13.webp)

The [IDK-13 template](https://www.ifs-erp.com/en/marketplace/implementation-docs-kit/13-interface-register) lists every interface between IFS Cloud and other systems: what flows, by which technology, who owns it and what happens to the legacy system behind it. In Implementer the same list is a register. Each interface is a row with an owner, a lifecycle state and an audit trail, and the rows feed the gate checklists and the test coverage view. For a wider view of the product see [Implementation support for IFS Cloud](https://www.ifs-erp.com/en/applications/implementer-implementation-support-for-ifs-cloud).

 
## What you get in the application

 **Interfaces** sits in the **Registers** group of the project menu, next to Risks, Issues, Change requests, CRIM objects and Defects. It opens as a list or a Kanban board; the **Board** and **List** buttons switch the view. The list columns are key (`INT-001` and so on), title, status, direction, technology, owner and due date. You can search by key or title, filter by status and switch between **Anyone** and **Mine**.

 Opening a row shows a drawer with the tabs **Fields**, **Links**, **Attachments** and **History**. The fields are in five groups:

 
- Scope: description, direction (inbound, outbound, bidirectional), source system, target system, data description, scope status (New in scope, Kept as it is, Being retired).
- Technical: technology (REST / OData, IFS Connect, file exchange, event, database link, manual, other), access (read-only or write), IFS API reference, frequency, volume per day, security notes, error handling.
- Legacy: legacy system, legacy decision (keep, replace with standard, rebuild, retire, not applicable), decision note.
- Delivery: specification reference, test evidence, go-live date, retire reason.
- Support: service account reference, permission set reference, authentication type, vendor contact, support owner, post-update check, removal steps. These hold names of accounts only, never a secret.

 
## How to use it

 
1. Open **Interfaces** and choose **New Interface**. Give it a title. The row gets its key and starts as **Identified**.
2. Fill the scope and technical groups. Choose **Propose for decision**; direction, source system, target system and technology must be set first.
3. The decision step is **Approve**. It needs the legacy decision. **Send back** returns the interface to Identified. The solution architect, technical solution manager and project managers hold this action.
4. **Mark as specified** needs the specification reference. **Start build** and **Submit for test** follow.
5. In test, **Test failed** sends the interface back to build and creates a defect in the Defects register, titled after the interface and pointing at it. **Accept** needs the test evidence and is held by the test lead, the system owner, the application consultant, the solution architect, the technical solution manager and project managers.
6. **Go live** needs the go-live date. **Retire** is available from every state except Retired and needs a reason.
7. Drag a card on the Board to run the same transition. The action buttons in the drawer header do the same thing.

 
## Screenshots

 ![Interface register as a list with status, direction, technology and owner columns](https://www.ifs-erp.com/images/implementer/idk-13-interfaces.png)

 *The interface register in list view with status, direction, technology and owner. Demo data.*

 
## How it maps to the template

 
| Template section | Implementer |
| --- | --- |
| Identification and flow (name, direction, systems, data) | Scope group on the interface |
| Mechanism and security (technology, access, frequency, volume) | Technical group; authentication in the Support group |
| Error handling | `error_handling` field |
| Legacy system and decision | Legacy group, decision recorded at **Approve** |
| Status and go-live | Lifecycle state, go-live date, test evidence |
| Credentials owner | Service account and permission set references, support owner |
| Scope of interfaces (IDK-02) | Scope status, counted on the scope statement |

 
## Gate and approval behaviour

 The register is evidence for four checklist items in the IDK-08 gates:

 
- `solution_confirmed.7`, interface register lists every required interface.
- `solution_established.4`, interfaces built and tested end to end. The Testing readiness stage reads interface state and scenario coverage.
- `go_live_authorised.12`, production connections in place. The handover readiness blocks a production interface without an account, permission set or authentication.
- `go_live_complete.6`, interfaces live and legacy handled. The cutover readiness flags an interface to retire or replace a legacy one with no legacy action task.

 A transition that lacks a required field opens a dialog asking for it. An action your role cannot take, or that is not allowed in the current state, appears greyed out with a tooltip giving the reason. Every transition and field change is written to the History tab.

 
## Not in the application yet

 
- Application cutover actions per interface are tasks in the cutover plan, not fields on the interface.
- The application does not call the interface endpoints. The IFS API reference is text you enter.
- There is no generated register document; the register is the template.

 
## Related

 
- Testing of interfaces: [Implementer: Test Strategy (IDK-17)](https://www.ifs-erp.com/en/marketplace/implementation-docs-kit/implementer-idk-17-test-strategy) and [SAT/ORT Test Script and Sign-off (IDK-18)](https://www.ifs-erp.com/en/marketplace/implementation-docs-kit/implementer-idk-18-sat-ort-test-script-and-signoff) cover how interfaces get tested.